image

FEATURES

  • Transom and mullion profiles are available in graduated dim. to meet varying structural requirements
  • All load-bearing profiles have a narrow face width of 50 mm and have small radiused edges
  • Aluminium cable channel for mullion/transom for subsequent installation on the profiles. Cable channel cover available in two design variants
  • Overlapping drainage principle as overall ventilation and drainage or as field ventilation and drainage
  • System-based security to RC 2/RC 3/FB4
  • Special profiles are available for vapour barrier and wall attachment and for attachment to existing substructures, plus a range of insert units (block vents, ventilation vents, doors, roof vents, block constructions) and façade fixing brackets
  • Base profile for simple ribbon window constructions, and for the transition to the ventilated façade

DESIGN PARAMETERS

Parameters Values
Face width 50mm
Dimensions Level 1 transom, 6 - 255 mm basic depth
Level 2 transom, 84 - 149 mm basic depth
Level 3 mullion, 50 - 250 mm basic depth
Maximum Weight Glass load upto 910Kgs
Glass Thickness 4mm - 62mm

PERFORMANCE PARAMETER

Parameter Testing Value Testing Standard
Air Permeability Class AE (>600 Pa) EN 13830
Water tightness Upto Class RE1200 (>600 Pa) EN 13830
Air borne sound insulation 720 Pa Upto 48 dB
Windload 2000 Pa EN 13116:2001-07

PRODUCTS